Wired or Portable? Choosing a Generator for a NH Winter

Twice in six years, a storm hit New Hampshire on October 29 and the lights stayed off for most of a week.

In 2011 it was an early snowstorm. Heavy, wet snow piled onto trees that still had their leaves, and limbs came down on power lines all over the state. About 47% of Eversource’s New Hampshire customers lost power, and it took roughly six and a half days to get everyone back. In 2017 it was wind and rain instead of snow. Same date, almost the same result: 41% of customers out, six and a half days to restore.

Then there was Thanksgiving Eve 2014. A snowstorm knocked out 41% of Eversource customers, and restoration took almost five days. A lot of families spent that holiday weekend in the dark.

So when customers ask us how long an outage they should plan for, our answer is a week. Not a night. A week.

A home generator solves most of that. Pick the wrong one, hook it up the wrong way, or set it in the wrong spot, though, and it can cause bigger problems than the outage itself. Here’s what we tell our own customers when they ask which kind to buy.

Cutaway of a New Hampshire home showing four systems that need electricity: boiler heating, well pump, sump pump, and refrigerator.

Your boiler needs electricity too

Most people think about the lights and the fridge first. In a New Hampshire winter, those are the easy part.

Heat. Your oil, propane, or gas boiler won’t fire without power. The burner, the controls, and the circulator pumps that push hot water through your baseboards all run on electricity. A full oil tank does nothing for you if the burner can’t start.

Water. If you’re on a private well, no power means no water. No flushing, no showers, no dishes. The pump is down in the well, and it needs electricity to bring water up.

The basement. A sump pump that stops during a soaking rain lets water rise in the pit, and then on the floor.

Pipes. A tight house holds its heat for a while. After a day or two with no heat in January, though, pipes in outside walls and crawlspaces start to freeze. A pipe that freezes and splits turns a power problem into a water damage problem.

So start with a short list: heat, water, sump pump, fridge. Those four decide what kind of generator makes sense for your house, and how big it needs to be.

Three ways to get backup power

What separates these three setups is mostly how the power gets into your house, and who has to be there to make it happen.

Three backup power options: portable generator with extension cords, portable with a house inlet, and standby generator with automatic backup.

Portable generator + extension cords

  • Connects: cords run through a door or window to a few appliances
  • Runs the boiler and well pump: usually not, since they’re wired in and have no plug
  • Who starts it: you, outside, in the storm
  • Fuel: gasoline, refilled every 8 to 10 hours
  • Best for: one-night outages (fridge, lamps, phones)

Portable generator + inlet and switch

  • Connects: one cord to an outdoor inlet; an interlock or transfer switch feeds the circuits you choose
  • Runs the boiler and well pump: yes
  • Who starts it: you, outside, in the storm
  • Fuel: gasoline, refilled every 8 to 10 hours
  • Best for: whole-house backup on a budget, when someone is home

Standby generator

  • Connects: wired in for good, with an automatic transfer switch
  • Runs the boiler and well pump: yes
  • Who starts it: it starts itself in about 10 seconds, even when you’re away
  • Fuel: propane tank or natural gas line
  • Best for: week-long outages, wells, winter travel, medical equipment

Portable with extension cords. It’s cheap and it gets you through a night. It can’t run your boiler or well pump, and the cord has to come in through a door or window left cracked open, which gives exhaust one more way inside. Gasoline also goes stale in 30 to 60 days without stabilizer. That’s a big reason so many portables won’t start on the one night you need them.

Portable with an inlet and an interlock or transfer switch. For a lot of homes, this is the sweet spot. A licensed electrician mounts a weatherproof inlet on the outside wall. Then you get either an interlock, a metal plate on your panel that keeps the main breaker and the generator breaker from both being on, or a small transfer switch panel wired to the circuits you pick.

In a storm you roll the generator out, plug in one cord, and flip a few breakers. Your boiler, well pump, and fridge come back on. The catch: someone has to be home to do it, refuel every 8 to 10 hours, and notice when the utility power returns. Not every panel has a matching interlock kit, so some older panels need the transfer switch instead.

Standby generator. This one sits on a pad beside the house, runs on propane or natural gas, and switches on by itself about 10 seconds after the power drops. You can be in Florida in February and your boiler keeps firing.

Here’s our honest take. A portable is a fine answer for a house where someone is always home and doesn’t mind standing in the sleet with a gas can at 2 a.m. If that’s not your house, a portable is the wrong answer, whatever it costs. If you’re on a well and you travel in winter, or anyone in the house depends on powered medical equipment, go standby.

Hooking it up: the part people get wrong

During a storm restoration in Brookline, New Hampshire, an Eversource lineworker was about to reconnect a broken line at the top of a pole when he heard a faint buzz. He also heard a generator running somewhere down the road. He tested the line before touching it. It was live.

A homeowner’s generator, wired in without a transfer switch, was pushing power backward up the service line. The transformer on the pole did what transformers do and stepped it up. On the far side, where the crew needed to put their hands, the line carried 7,200 volts. The foreman told Eversource he’d been doing the job for 25 years and had never seen it happen before.

That’s called backfeed, and it’s why New Hampshire’s State Fire Marshal is blunt about a few things:

  • No homemade cords. A cord with a plug on both ends, run from the generator into a dryer outlet or wall outlet, is the classic way to backfeed. Never build or use one.
  • A transfer switch or interlock is required any time a generator connects to your house wiring. It makes it physically impossible for the generator and the utility to feed your panel at the same time.
  • Licensed trades do the work. Unless you own and live in the single-family home and do the job yourself, state rules require a licensed master electrician for the hookup and a licensed gas fitter for any fuel line. Your town may also require permits and inspections, even when the generator is portable.

A standby generator touches three trades at once: electrical work at the panel, gas piping from the propane tank or gas meter, and a check of the heating system it’s meant to keep running. Al Terry does plumbing, heating, and electrical under one roof, so one company can handle all three and stand behind the whole job.

Carbon monoxide: the part that can kill you

About 85 people in the U.S. die every year from carbon monoxide made by gasoline portable generators, and 81% of those deaths happen at home. The most common reason they were running the generator: a weather-related power outage. One portable can put out as much CO as hundreds of cars, and you can’t smell it. People can pass out before they notice the dizziness or the nausea.

Portable generator rules

  • Outside only. Not in the garage, the basement, the shed, or on the porch. Opening the garage door or a window does not let in enough air to make it safe.
  • At least 20 feet from the house, exhaust pointed away from doors, windows, and vents. Keep the windows on that side of the house closed.
  • Out in the open. In a snowstorm the urge is to tuck the generator up against the house or under the deck to keep it dry. Don’t. Besides the CO, a hot engine near a wooden deck or porch is a fire waiting to happen. Use a cover made for running generators.
  • Buy one with automatic CO shutoff. Look for PGMA G300 or UL 2201 on the box. Federal safety regulators estimate those standards cut CO deaths by 87% and nearly 100%.
  • If it shuts itself off for CO, move it farther from the house before you start it again.

Standby owners, this part is for you

A permanently installed generator is not CO-proof. After Hurricane Ida in 2021, federal investigators traced carbon monoxide in 105 homes back to the home’s own standby generator. Where investigators could measure, most of those units sat more than 5 feet from the house, the minimum distance the installation standard calls for. The exhaust got in anyway, usually through the soffit vents under the roof overhang. In some homes it had traveled more than 25 feet. Where a wall sat close to the exhaust side, it pushed the fumes up toward second-floor windows.

Generator placement guidance showing a portable at least 20 feet from the house with exhaust directed away, standby placement considerations, and CO alarms.

Staff at the Consumer Product Safety Commission have since asked the committee that writes the standard to raise that minimum from 5 feet to at least 25 feet. Until the code catches up, placement is on you and your installer. Before a standby unit goes in, ask:

  • Which side does the exhaust come out of, and what’s in its path?
  • How far is it from soffit vents, windows, the bulkhead, the dryer vent, and the boiler or water heater vent?
  • Is there a wall, fence, or woodpile nearby that could bounce the exhaust back toward the house?

Every generator home needs CO alarms

New Hampshire law requires a CO alarm in single-family homes built or substantially renovated after January 1, 2010, if the house has an attached garage or any fuel-burning appliance. Rentals and multi-unit buildings with those features need them too. If your house is older, the law may not require one at all.

Get them anyway. Put one on every level and outside each sleeping area, and test them monthly. If one goes off, get everybody outside first and call 911 from the driveway. A CO alarm is the cheapest thing in this whole article.

How big, and how much fuel

The well pump sets the size. Motors pull a surge for the first second or two after they start, often two to three times what they draw once running. A 3/4-horsepower well pump can need 3,000 to 4,500 watts just to get going. The rule installers use: take the well pump’s starting watts and add everything else that will be running at the same moment. That total is your minimum.

Your heating system changes the answer a lot. A boiler’s circulator pump draws only 100 to 300 watts. A heat pump can draw 4,500 to 7,500. So two houses the same size can need very different generators. A home with a fuel-fired boiler or furnace and a well is often well served by a 14 to 18 kW unit. Heat with a heat pump and you could be looking at 22 to 24 kW.

Check the panel before you fall for a generator. A whole-house transfer switch on an older 100- to 150-amp panel often means upgrading to 200-amp service first. Better to learn that during the estimate than on install day.

Propane math for a New Hampshire week. If a gas main runs past your house, natural gas comes down the pipe and never needs a delivery. Much of New Hampshire doesn’t have that option, so a lot of standby units here run on propane.

A popular 22 kW unit burns about 2.5 gallons an hour at half load. Propane tanks are only filled to 80%, so a 500-gallon tank holds about 400 usable gallons. That’s roughly 6.6 days at half load, or about 9 days at the lighter load most houses actually draw. The 2011 and 2017 outages each ran about 6.6 days. Cutting it close.

One more cold-weather catch. A tank that’s running low can’t turn liquid propane into gas fast enough on a below-zero night to keep a big generator fed. Keep the tank topped up all winter, and if the same tank feeds your boiler or furnace, size it for both jobs.

Before the next storm: a checklist for this week

  • Start your portable generator outside and run it with something plugged in for 15 minutes.
  • Drain old gas or treat it with stabilizer. Gas left over from summer may already be stale.
  • Look at how your portable connects. If the answer is a cord into a dryer or wall outlet, stop using it that way and call an electrician.
  • Pick the spot now: 20 feet from the house, exhaust aimed away, with a path you can shovel.
  • Test every CO and smoke alarm. Clocks fall back on Sunday, November 1, so swap batteries that weekend.
  • Check your propane gauge and schedule a fill before the cold sets in.
  • Standby owners: confirm the weekly self-test is running, the annual service is done, and leaves and brush are cleared from around the unit.
  • On a well? When a storm is in the forecast, fill jugs of water for drinking and flushing.
  • Test the sump pump: pour a bucket of water into the pit and make sure it kicks on.
  • Save your utility’s outage map on your phone: Eversource, Unitil, Liberty, or the New Hampshire Electric Co-op.

Not sure which setup fits your house?

That’s hard to answer from a blog post. Call us at (603) 485-4205 and we’ll come take a look: your panel, your well pump, your boiler, where a generator could sit, and whether propane or natural gas makes sense. You’ll know which of the three setups fits your house, and what it will cost, before the next October 29.

Al Terry has been keeping New Hampshire homes warm and running since 1976. Every new installation carries our 5-year warranty, and financing is available. Diamond Club members get front-of-the-line service, which counts for a lot the morning after a storm.

See our home generator services

More Practical Home Advice You Can Trust

Our homes face unique challenges in New Hampshire’s climate. These articles break down heating, plumbing, and electrical topics in plain language—helping you understand what matters, what can wait, and how to protect your home through every season.

warranty stamps

Our Commitment to Your

PEACE OF MIND

5-year warranty on all new installations
AND 2-year warranty on all repairs!